ComfortAdvisor.ai
Preliminary home comfort report
Internal reviewer preview
Static internal surface for 2433 135th Place Southwest, Lynnwood, WA 98087. This route intentionally includes reviewer notes and placeholder pricing internals that should never appear on the customer report route.
Internal only. No auth exists in v0, so deploy behind Cloudflare Access before sharing.
Report ID
demo-lynnwood-2433
Status
Preliminary static demo
Tenant radius
10 miles
Raw assumptions
Home has an existing ducted forced-air system
MediumVerify by: Inspect existing furnace/air handler and duct layout
Customer visible: yes
Two-story layout may create upstairs cooling imbalance
MediumVerify by: Ask homeowner and inspect room temperatures/duct layout
Customer visible: yes
Large picture windows may increase localized solar gain
MediumVerify by: Confirm window orientation and shading
Customer visible: yes
No major electrical, duct, or structural complications included in price placeholder
LowVerify by: Site visit
Customer visible: yes
Internal pricing placeholders
- Labor rate
- $175/man-hour
- Material markup
- 15% placeholder
- Permit allowance
- $500
- Complexity multiplier
- 1
Ac Replacement Existing Gas Furnace
Hours: 32-56 | Equipment/material: $5,000-$9,000
Ducted Heat Pump Dual Fuel
Hours: 48-88 | Equipment/material: $8,500-$16,000
Ducted Heat Pump Air Handler Electric Backup
Hours: 56-96 | Equipment/material: $9,000-$18,000
Single Zone Mini Split
Hours: 24-44 | Equipment/material: $3,500-$7,000
Placeholder only. Replace with tenant-approved pricing before any customer use.
Suggested talking points
- Lead with right-sizing and comfort distribution rather than tonnage alone.
- Ask whether upstairs rooms get warm before proposing a larger central system.
- Confirm the existing furnace and duct condition before choosing AC-only, dual-fuel, or all-electric.
- Frame the report as a stronger starting point for field verification, not a final quote.
Source notes
- Seeded public-record and listing-note summary only; no live lookup was run in v0.
- Better Air NW contact, financing, equipment brands, and schedule URL require Justin/tenant verification.
- Utility and rebate details are placeholders and should not be treated as production eligibility.
- Customer report intentionally omits raw labor, markup, and internal reviewer notes.
Audit log sketch
- Report fixture loaded for demo-lynnwood-2433
- Seed address confirmed as static Lynnwood demo
- Manual J-style preliminary estimate generated from fixture assumptions
- Customer-safe report view assembled without internal pricing inputs
Equipment options to verify
Mitsubishi ducted inverter heat pump package
Mitsubishi | Better/Best
Placeholder until actual Better Air NW model families and pricing are provided.
American Standard ducted comfort package
American Standard | Good/Better
Placeholder until actual Better Air NW model families and pricing are provided.
Targeted ductless mini-split comfort zone
Mitsubishi | Add-on/Alternative
Useful for upstairs/window-heavy comfort issues.
Site visit checklist
- Duct sizing and static pressure
- Existing equipment model, age, and condition
- Electrical panel capacity
- Gas line and venting condition, if applicable
- Refrigerant line-set route and condition
- Outdoor unit location and clearances
- Condensate path
- Upstairs comfort complaints
- Return-air path
- Window exposure and shading
- Visible attic or crawl insulation, if accessible
- Permitting requirements